Frameless BLDC Motors for Robot Joints: How to Choose and Integrate Them
A frameless BLDC motor is a brushless DC motor supplied as a separate stator and rotor, without a housing, shaft, bearings or feedback device. Robot joint designers build these two parts directly into the joint structure, which gives a shorter, lighter and stiffer joint than a housed motor would. This guide explains why robot joints use frameless motors, which specifications decide the choice, what the integration work involves, and when an integrated actuator is the better route. For the basics of brushless motors, see What Is a BLDC Motor?
What Is a Frameless BLDC Motor?
A housed BLDC servo motor is a complete unit: stator, rotor, housing, endbells, bearings, output shaft, encoder, often a brake, and connectors. Kollmorgen describes a frameless motor as a wound stator and a separate permanent-magnet rotor, without the other components of a housed motor. The stator is bonded or clamped into a bore in the machine, and the rotor is mounted on the machine's own shaft, which runs in the machine's own bearings.

The same product is sold as a frameless brushless DC motor, a frameless torque motor or a frameless BLDC kit. Electrically it is a permanent magnet brushless motor, and it needs a drive and a rotor position sensor like any other BLDC motor.
Why Robot Joints Use Frameless Motors
Shorter joints
A housed motor coupled to a reducer brings its own housing, endbells, bearings and coupling. A frameless motor shares the joint housing and bearings and drives the reducer input directly. The EYOU PHU and RHU user manual notes that the frameless design removes conventional transmission parts and makes the joint lighter and more compact.
High torque in a flat shape: the D²L rule
The torque a motor produces scales roughly with the square of its rotor diameter D multiplied by its active stack length L. Kollmorgen describes its frameless torque motors as taking advantage of the D²L rule:
T ∝ D2 · L
Doubling the length doubles torque. Doubling the diameter multiplies it by four. In a robot joint the axial length is usually the tighter limit, so high torque BLDC motors for joints are large in diameter and short in length.

Hollow center
Torque is produced at the air gap between rotor and stator. The center of the rotor contributes little, so a frameless rotor can be a ring with a large bore. That space can carry cables, a through shaft or the output side of the encoder, which keeps wiring inside the joint.
Stiffness and heat
Without a coupling between motor and reducer, the drive train has one fewer compliant element. The stator is fixed to the joint housing, so the heat produced in the windings conducts directly into the housing.
Key Specs When Choosing a Frameless BLDC Motor
Start from the joint output and work back to the motor. For a reducer with ratio i and efficiency η:
Tmotor = Touti · η nmotor = nout · i
For example, a joint that needs 20 N·m continuous output torque at 30 rpm through a 101:1 harmonic reducer, with an assumed reducer efficiency of 70%, requires about 0.28 N·m continuous motor torque at about 3,030 rpm. For a duty cycle with varying torque, compare the RMS torque with the motor's continuous rating, and the highest torque in the cycle with the peak rating:
Trms = √(Σ Tk2 tkΣ tk)
Then check the following figures on the motor datasheet.
| Specification | What it describes | What to check |
|---|---|---|
| Continuous torque | Torque the motor can deliver without exceeding its winding temperature limit | The mounting and heat sink conditions used for the rating; a sealed joint may cool less |
| Peak torque | Short-term torque for acceleration and impacts | Allowed duration; torque becomes nonlinear in current near peak as the iron saturates |
| Torque constant Kt | Torque per ampere (N·m/A) | Whether the drive can supply the current for peak torque |
| Back-EMF constant and bus voltage | Voltage generated per unit speed | Maximum motor speed at your bus voltage, with margin for the current controller |
| Motor constant Km | Torque per square root of copper loss | Higher Km means less heat for the same torque |
| Thermal resistance and temperature limit | Winding temperature rise per watt of loss | Heat path through the joint housing; magnet temperature limit |
| Outer diameter, inner bore, stack length | Fit in the joint | Bore size for cables or a shaft |
| Pole count | Number of magnet poles | Electrical frequency at top speed; encoder resolution needed for smooth FOC |
| Cogging torque | Torque ripple from magnets and slots with no current | Smoothness at low speed and in hand-guiding |
The motor constant combines torque and losses:
Km = T√Ploss
It is the most direct measure of how much torque a motor produces for each watt of heat, which in a closed robot joint is often the limiting factor. One design factor behind it is slot fill: the share of each stator slot filled with copper. More copper lowers winding resistance and losses for the same torque. How to Increase Robot Actuator Power Density covers this and the other measures that raise torque per volume.
Integration Challenges
A frameless motor moves several tasks from the motor supplier to the joint designer.
- Bearings and concentricity: the air gap between rotor and stator is small. If the rotor runs off center, unbalanced magnetic pull loads the bearings and torque ripple and noise rise. The housing bore, shaft and bearings must hold the rotor centered under load.
- Assembly: the rotor magnets are strongly attracted to the stator core. Inserting the rotor needs guiding fixtures to prevent damage to magnets and windings.
- Encoder mounting and commutation: FOC needs the rotor electrical angle in each control cycle. The motor-side encoder must be fixed to the rotor shaft, and its offset from the rotor magnets must be calibrated. Many joints add a second, output-side encoder. FOC Control for Robot Actuators explains what happens if this angle is wrong.
- Heat path: heat must pass from the windings to the housing and out to the air. Air between the windings and the housing conducts heat poorly. EYOU pots the motor stator with a thermally conductive compound to give heat a solid path to the housing; Robot Actuator Thermal Management describes the full thermal design.
- Drive matching and tuning: the drive's current and voltage ratings must match the motor, and the current loop must be tuned to the winding resistance and inductance before the speed and position loops can be tuned.
- Validation: thermal tests at the intended duty cycle, life tests, EMC tests and checks that each assembled joint performs the same.
Buy a Frameless Motor or an Integrated Actuator?
A robot builder can design joints around frameless motors or buy integrated actuators that already contain the motor, reducer, encoders, brake and drive. The table compares the two routes.
| Factor | Frameless motor and in-house joint | Integrated actuator |
|---|---|---|
| Design freedom | Full control of geometry and parts | Choice among the sizes in a product series |
| Engineering work | Mechanical, electrical, firmware and test development | Mounting, wiring and configuration |
| Time to a working joint | Months, depending on team and test scope | Short, once a model is selected |
| Testing | Thermal, life and EMC tests run by the builder | Tested by the supplier as a unit |
| Consistency in volume | Depends on the builder's assembly process | Depends on the supplier's production line |
| Unit cost | Can be lower at high volume after development is paid off | Includes the supplier's engineering and testing |

A frameless motor makes sense when the joint has an unusual shape, when volumes are high enough to pay back development, or when the team already has motor drive and joint design experience. For most humanoid robot, collaborative arm and automation projects, an integrated actuator shortens development and moves joint-level testing to the supplier. What Is Inside a Robot Actuator lists the parts an integrated actuator contains.
Frameless Torque Motors Inside EYOU Actuators
EYOU designs its own motors and integrates them into its actuators. The PHU and RHU series combine a frameless torque motor, a brake and a precision harmonic reducer with dual absolute encoders on the motor side and the output side. The user manual describes the motor as an independent rotor and stator integrated inside the joint and closely combined with the harmonic reducer. The RP series pairs a brushless torque motor with a planetary reducer for humanoid legs, and its motor reaches a slot fill of at least 80%. The motor stators are potted for heat transfer.
| Series | Reducer | Motor | Typical positions |
|---|---|---|---|
| PHU enhanced harmonic actuator | Harmonic | Frameless torque motor | Collaborative arms, humanoid upper body, industrial automation |
| RHU humanoid harmonic actuator | Harmonic | Frameless torque motor | High-precision humanoid positions |
| RP humanoid planetary actuator | Planetary | Brushless torque motor | Humanoid legs |
Specifications and manuals are available in the download center. If you are deciding between frameless motors and integrated actuators, send the joint position, output torque and speed, duty cycle and size limits to our application engineers, and we will recommend a model.
FAQ
A frameless BLDC motor is a brushless DC motor supplied as a separate wound stator and permanent magnet rotor, without a housing, shaft, bearings or encoder. The machine provides those parts, and the stator and rotor are built directly into its structure.
A frameless motor shares the joint housing and bearings, so the joint is shorter and lighter. Its large-diameter, short shape gives high torque in little axial length, its ring rotor leaves a bore for cables, and its stator conducts heat directly into the housing.
Work back from the joint output torque and speed through the reducer ratio and efficiency to the required motor torque and speed. Compare RMS torque over the duty cycle with continuous torque, and maximum torque with peak torque. Then check the torque constant, bus voltage, motor constant, thermal resistance, dimensions and cogging torque.
The joint designer must keep the rotor concentric in the stator, assemble the rotor against strong magnetic attraction, mount and calibrate the encoder, provide a heat path from the windings to the housing, match and tune the drive, and validate the joint through thermal, life and EMC tests.
It depends on the project. A frameless motor gives full design freedom and can lower unit cost at high volume. An integrated actuator such as an EYOU PHU, RHU or RP actuator removes most joint engineering and testing work and shortens development.