NOVEMBER 2, 2026How to Manually Control PHU Series Brake via SDO?1. Ensure firmware version is PHU V0.0.0.45 or above2. Write 0 to 2110-00 for manual brake controlWrite 0 to 2111-00 to release brake; write 1 to close brake.